Entity

Time filter

Source Type


Xue A.,North China Electrical Power University | Wang R.,Yunnan Electrical Power Dispatching and Controlling Center | Wang B.,North China Electrical Power University | Bi T.,North China Electrical Power University | Huang S.,North China Electrical Power University
Dianli Xitong Zidonghua/Automation of Electric Power Systems | Year: 2013

The minimum maintenance model for relay is developed from the viewpoint of relay reliability and maintenance economy. Based on the proposed model, the optimal replacement strategy is proposed. Specifically, the Poisson distribution fitting and Cramer-von Mises goodness of fit test are used to determine the failure characteristics of protection devices; and the log-normal distribution is used to fit repair features of protection device. With the above failure and repair property, the minimum maintenance model is constructed. Furthermore, the unit life-cycle cost is applied in protection device reliability assessment to formulate the replacement strategy with the lowest unit life-cycle cost as the objective. Finally, the optimal replacement cycle for a field operating relay is obtained with the proposed strategy, with the double protection considered. The availability of the proposed strategy is verified by the simulation results. ©2013 State Grid Electric Power Research Institute Press. Source


Zhu T.,Yunnan Electrical Power Dispatching and Controlling Center | Duan R.,Yunnan Electrical Power Dispatching and Controlling Center | Wang Z.,Zhejiang University
Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control | Year: 2015

Lots of small hydropower stations gather in the west of Yunnan province, where are far from Yunnan main power grid in electric distance, and therefore dynamic stability in this area is serious. Based on the disturbed temporal trajectory dynamic performance index and cost of investment, SVC, STATCOM and TCSC single FACTS element integrated optimization model is established respectively in order to improve the dynamic stability and transmission ability. And an improved difference evolution algorithm is applied for the different types of single FACTS element configuration parameter and capacity. The result shows that STATCOM is the best single FACTS element to improve dynamic stability Western Yunnan power grid. ©, 2015, Power System Protection and Control Press. All right reserved. Source


Li B.-Y.,Yunnan Electrical Power Dispatching and Controlling Center | Shi H.-C.,Yunnan Electrical Power Dispatching and Controlling Center | Zhai H.-Y.,Yunnan Electrical Power Dispatching and Controlling Center | Zhao M.,Yunnan Electrical Power Dispatching and Controlling Center | You H.,Yunnan Electrical Power Dispatching and Controlling Center
Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control | Year: 2014

Contra posing to the insufficiency and problems existing in the traditional relay protection setting and coordination calculation management model, this paper develops a set of relay protection setting and coordination calculation process management system applicable to provincial, prefecture and county levels dispatching system. The system is based on the SOA and seamlessly integrates all the functions of the relay protection setting calculation related modules on the unified data platform, realizing the examination, approval and implement of the closed loop management of drawing of protection, and the basic data of protection setting calculation such as equipment parameters' remote filling, parameter calculation modeling, protection setting calculating and auto-generating relay protection setting value notification model. This system has been successfully used in the relay protection setting calculation for the Yunnan Electric Power Grid's provincial, prefecture and county levels dispatching system. ©, 2014, Power System Protection and Control Press. All right reserved. Source