The selection or procurement of blood collection devices in healthcare facilities is often an underestimated issue. This is probably due to different factors including the lack of knowledge of policymakers, hospital administrators and even laboratory managers about the importance of preanalytical quality and phlebotomy process, as well as to the absence of reliable guidelines or recommendations on how to precisely assess the quality of blood collection devices around the globe. With the awareness that a gap remains between manufacturers' and local validation of blood collection devices, the Working Group for Preanalytical Phase (WG-PRE) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has drafted a consensus document aimed to provide a set of essential requisites, technical criteria (e.g. presence of physical defects, malfunctioning, safety problems) and clinical issues for supporting laboratory professionals in organization blood collection tubes tenders and validating new devices before local routine implementation. The laboratory professionals should also make sure that the tenders accurately and strictly define the responsibilities for validation experiments and the potential consequences in the case the validation outcome shows that tubes due not fulfill the expectations. © 2016 by De Gruyter.


Simundic A.-M.,University of Zagreb | Simundic A.-M.,Working Group for Preanalytical Phase WG PRE | Church S.,Working Group for Preanalytical Phase WG PRE | Cornes M.P.,Working Group for Preanalytical Phase WG PRE | And 18 more authors.
Clinical Chemistry and Laboratory Medicine | Year: 2015

Background: An observational study was conducted in 12 European countries by the European Federation of Clinical Chemistry and Laboratory Medicine Working Group for the Preanalytical Phase (EFLM WG-PRE) to assess the level of compliance with the CLSI H3-A6 guidelines. Methods: A structured checklist including 29 items was created to assess the compliance of European phlebotomy procedures with the CLSI H3-A6 guideline. A risk occurrence chart of individual phlebotomy steps was created from the observed error frequency and severity of harm of each guideline key issue. The severity of errors occurring during phlebotomy was graded using the risk occurrence chart. Results: Twelve European countries participated with a median of 33 (18-36) audits per country, and a total of 336 audits. The median error rate for the total phlebotomy procedure was 26.9 % (10.6-43.8), indicating a low overall compliance with the recommended CLSI guideline. Patient identification and test tube labelling were identified as the key guideline issues with the highest combination of probability and potential risk of harm. Administrative staff did not adhere to patient identification procedures during phlebotomy, whereas physicians did not adhere to test tube labelling policy. Conclusions: The level of compliance of phlebotomy procedures with the CLSI H3-A6 guidelines in 12 European countries was found to be unacceptably low. The most critical steps in need of immediate attention in the investigated countries are patient identification and tube labelling. © 2015 by De Gruyter.

Loading Working Group for Preanalytical Phase WG PRE collaborators
Loading Working Group for Preanalytical Phase WG PRE collaborators