Entity

Time filter

Source Type


Nassalski A.,Soltan Institute for Nuclear Studis | Moszynski M.,Soltan Institute for Nuclear Studis | Syntfeld-Kazuch A.,Soltan Institute for Nuclear Studis | Szczesniak T.,Soltan Institute for Nuclear Studis | And 4 more authors.
IEEE Transactions on Nuclear Science | Year: 2010

The performance of multi pixel photon counters (MPPC) of 3 mm × 3 mm size, with 14400 and 3600 pixels, were studied by means of the signal from a laser light pulser and using the 3 mm × 3 mm × 20 mm LSO pixel scintillator. Special attention was paid to measure number of fired pixels, generated by the light of pulser and that of the LSO crystal, using a direct method of a comparison of the light peak position in the pulse height spectrum with that of the single photoelectron. The tests of the LSO crystal showed 1550 ± 80 fired pixels per MeV in the MPPC with 14400 pixels assuring a good linearity of the response up to about 1 MeV energy of gamma rays absorbed in the LSO crystal. Energy resolution of 14.8% for 662 keV gamma rays from 137Cs source and a time resolution of about 850 ps for 511 keV annihilation quanta were limited by a rather low number of the fired pixels compared to the number of photoelectrons in photomultipliers. © 2010 IEEE. Source