Shanxi Zhongfu Nuclear Instrument Co.

Taiyuan, China

Shanxi Zhongfu Nuclear Instrument Co.

Taiyuan, China
SEARCH FILTERS
Time filter
Source Type

Qiao M.-J.,Shanxi Zhongfu Nuclear Instrument Co Ltd | Zhang J.,Shanxi Zhongfu Nuclear Instrument Co Ltd | Chang G.-R.,Shanxi Zhongfu Nuclear Instrument Co Ltd | Liu Y.,Shanxi Zhongfu Nuclear Instrument Co Ltd | Guo X.-R.,Shanxi Zhongfu Nuclear Instrument Co Ltd
Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology | Year: 2016

The GM counter high voltage circuit is introduced, this circuit usually used in portable nuclear radiation measuring instrument. The high voltage circuit through each function module forms closed-loop control, which controls feedback adjust voltage, reduces the interference, improves the stability. The test results show that the circuit can work normally, the detector voltage quickly reaches the expected value, the numerical stability, small ripple coefficient, makes the reliability of the measuring instrument and availability is greatly increased. The high voltage circuit has been successfully used in portable gamma dose rate meter, in the related nuclear radiation measurement circuit design has certain application value. © 2016, Editorial Board of Nuclear Electronics & Detection Tech. All right reserved.


Wang C.-Z.,Shanxi Zhongfu Nuclear Instrument Co. | Zhang J.,Shanxi Zhongfu Nuclear Instrument Co. | Shen Y.,Shanxi Zhongfu Nuclear Instrument Co. | Bai N.,Shanxi Zhongfu Nuclear Instrument Co. | And 2 more authors.
Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology | Year: 2013

The sensitivity of GM counter is to be improved by the method of energy compensation which is to reduce the energy response effect at low energy region. If the shielding layer thickness and the size of hole part are determined by test experiment, the process will be very complicated. This paper verifies a simple method developed to calculate compensation conditions, also try to shorten the test cycle and simplify the calculation process by finding the right compensation conditions through software analysis base on hypothesizes, and finally prove the accuracy of the method by the energy response experiment of the GM counter. Comparing the calculated results in theory with the experimental results, the two results are basically consistent and both of them meet the requirements of energy response.


Shen Y.,Shanxi Zhongfu Nuclear Instrument Co. | Song J.-X.,Shanxi Zhongfu Nuclear Instrument Co. | Deng C.-M.,Shanxi Zhongfu Nuclear Instrument Co. | Meng D.,Shanxi Zhongfu Nuclear Instrument Co. | And 3 more authors.
Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology | Year: 2011

The plant health personnel entrance door access control equipment C1 door for the study, drawing on advanced foreign companies and domestic pollution monitoring and out of the door staff developed a new instrument equipment. Referred to as C1 gate, C1 entrance doors for the first barrier to health, to monitor staff access to the nuclear island, the body is contaminated, as well as some other contamination contamination of the instrument. Nuclear power plant management level can be set alarm thresholds for each channel, if the police find body parts pollution, and in accordance with the provisions of the nuclear power plant decontamination processes. Pollution is not normal to leave the main body, simulation and system design capabilities to do a brief introduction.


Yao Y.-G.,Shanxi Zhongfu Nuclear Instrument Co. | Deng C.-M.,Shanxi Zhongfu Nuclear Instrument Co. | Zhang J.,Shanxi Zhongfu Nuclear Instrument Co. | Meng D.,Shanxi Zhongfu Nuclear Instrument Co. | And 3 more authors.
Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology | Year: 2011

It is based on tool monitor in Qin Shan Nuclear Power Plant for the object of study, and manufacture a tool monitor simulator. The device is designed to automatically emulate-monitor the contamination level of objects for training students. Once if the tool monitor reports the contamination, the students can handle properly. The brief introduction of main function and system design of the simulator are presented in the paper.


Wang Z.-A.,Shanxi Zhongfu Nuclear Instrument Co. | Yao Y.-G.,Shanxi Zhongfu Nuclear Instrument Co. | Deng C.-M.,Shanxi Zhongfu Nuclear Instrument Co. | Bai N.,Shanxi Zhongfu Nuclear Instrument Co. | And 2 more authors.
Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology | Year: 2011

In the Real-Time Supervision System of Personal Dose, the Reader's main function is to communicate between Dosimeter and Supervision Software in computer. The Dosimeter measure the personal dose and rate, and transmit them to the Supervision Software by Reader. The Supervision Software using Reader to set and assign dosimeter, also do the Entry/Exit control management. The brief introduction of main function and system design of the Reader are presented int the paper.


Song J.-X.,Shanxi Zhongfu Nuclear Instrument Co. | Sheng Y.,Shanxi Zhongfu Nuclear Instrument Co. | Deng C.-M.,Shanxi Zhongfu Nuclear Instrument Co. | Zhang J.,Shanxi Zhongfu Nuclear Instrument Co. | And 2 more authors.
Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology | Year: 2011

In order to protect the hands and feet of personnel engaged in nuclear, draw on advanced hands and feet contamination monitor, we design a new radiation protection instrumentation. It describes the composition of the hands and feet contamination monitor, and software program design. It describes the hardware monitor software, firmware and computer programming techniques. If device found your hand and foot surface is contamination, it will prompt you to decontamination, to protect your hands and feet of safety.