Time filter

Source Type

Jin S.,Science and Technology on Electrical Test and Measurement Laboratory | Jin S.,Key Laboratory of Instrumentation Science and Danamic Measurement | Jin H.,Science and Technology on Electrical Test and Measurement Laboratory | Jin H.,Key Laboratory of Instrumentation Science and Danamic Measurement | And 5 more authors.
Chinese Journal of Sensors and Actuators | Year: 2014

Two buffer protection structure of the missile-borne is put forward for missile parameters test failure due to deformation or damage in penetration test environment by high impact, Level 1 buffer is high mechanical strength steel protective shell and Level 2 is aluminum foam nested within the machined shell. It proves that under the environment of 100 000 gn high impact the recorder can store and read back the test data reliably after penetrating 3 layers concrete target.

Loading Science and Technology on Electrical Test and Measurement Laboratory collaborators