Stolyarov I.N.,Roentgenprom JSC
Biomedical Engineering | Year: 2013

Methods for reduction of the working temperature of X-ray tube bearings are discussed. The results of experimental testing of the thermal resistance to anode heat flux provided by most common models of X-ray tube bearings are presented. © 2013 Springer Science+Business Media New York. Source


Konoplev E.E.,Luch Scientific and Production Association | Stolyarov V.N.,Roentgenprom JSC | Stolyarov I.N.,Roentgenprom JSC
Biomedical Engineering | Year: 2011

The use of a titanium body for manufacture of rotating anodes of diagnostic X-ray tubes is suggested. The results of metallographic analysis of a composite anode made of titanium, molybdenum, and tungsten are discussed. Titanium is demonstrated to be the optimal material of the anode body. Comparative analysis of temperature fields of two anodes made of titanium and molybdenum is presented. © 2011 Springer Science+Business Media, Inc. Source


Stolyarov V.N.,Roentgenprom JSC
Biomedical Engineering | Year: 2012

The impact of different methods of composite anode tungsten layer processing on X-ray tube radiation intensity is discussed. The results of the analysis of tungsten layer surface samples studied by various methods are reported. The results of the X-ray tube radiation intensity measurement are discussed for each sample. © 2012 Springer Science+Business Media, Inc. Source


Gurzhiev A.S.,National Research Nuclear University MEPhI | Gurzhiev S.N.,Roentgenprom JSC | Miroshnikov E.M.,Roentgenprom JSC | Novikov V.P.,Roentgenprom JSC
Biomedical Engineering | Year: 2011

An experimental comparative study of the efficiency of three methods for measurement of the resolution of digital radiographic systems is described. An algorithm for subpixel angular projection was constructed. This algorithm allows the resolution of X-ray camera and test object to be measured using a narrow slit and sharp edge. Test results obtained using various methods are compared. © 2011 Springer Science+Business Media, Inc. Source


Lobanov I.S.,Roentgenprom JSC | Stolyarov V.N.,Roentgenprom JSC | Stolyarov I.N.,Roentgenprom JSC
Biomedical Engineering | Year: 2012

Application of a vibration diagnosis method for analyzing the quality of rotating anode X-ray tubes is described. The experimental results of testing of vibration characteristics of rotating elements of X-ray tubes are presented. © 2012 Springer Science+Business Media, Inc. Source