Hrazdan, Armenia
Hrazdan, Armenia

Time filter

Source Type

Sargsyan K.B.,Razdan 5 Gasprom Armeniya | Eritsyan S.K.,Razdan 5 Gasprom Armeniya | Petrosyan G.S.,Razdan 5 Gasprom Armeniya | Avtandilyan A.V.,Razdan 5 Gasprom Armeniya | And 2 more authors.
Thermal Engineering (English translation of Teploenergetika) | Year: 2015

Results of thermal tests of 480-MW power-generating Unit 5 of Razdan Thermal Power Plant (hereinafter, Razdan-5 power unit) are presented. The tests were carried out by LvivORGRES after an integration trial of the power unit. The aim of the tests was thermal characterization of the steam boiler and the steam turbine when the power unit operates as a combined-cycle plant. The economic efficiency of the boiler and the turbine and the environmental characteristics of the power unit are determined and the calculated and the actual values are compared. The specific heat gross and net rates required for the power unit to generate the electric power are established. © 2015, Pleiades Publishing, Inc.

Loading Razdan 5 Gasprom Armeniya collaborators
Loading Razdan 5 Gasprom Armeniya collaborators