Winterswijk, Netherlands

Weykamp C.,Queen Beatrix Hospital | Weykamp C.,European Reference Laboratory | John G.,Norwich University | Gillery P.,University Hospital of Reims | And 8 more authors.
Clinical Chemistry | Year: 2015

BACKGROUND: A major objective of the IFCC Task Force on Implementation of HbA1c Standardization is to develop a model to define quality targets for glycated hemoglobin (Hb A1c). METHODS: Two generic models, biological variation and sigma-metrics, are investigated. We selected variables in the models for Hb A1c and used data of external quality assurance/proficiency testing programs to evaluate the suitability of the models to set and evaluate quality targets within and between laboratories. RESULTS: In the biological variation model, 48% of individual laboratories and none of the 26 instrument groups met the minimum performance criterion. In the sigmametrics model, with a total allowable error (TAE) set at 5 mmol/mol (0.46% NGSP), 77% of the individual laboratories and 12 of 26 instrument groups met the 2σ criterion. CONCLUSIONS: The biological variation and sigma-metrics models were demonstrated to be suitable for setting and evaluating quality targets within and between laboratories. The sigma-metrics model is more flexible, as both the TAE and the risk of failure can be adjusted to the situation - for example, requirements related to diagnosis/monitoring or international authorities. With the aim of reaching (inter)national consensus on advice regarding quality targets for Hb A1c, the Task Force suggests the sigma-metrics model as the model of choice, with default values of 5 mmol/mol (0.46%) for TAE and risk levels of 2σ and 4σ for routine laboratories and laboratories performing clinical trials, respectively. These goals should serve as a starting point for discussion with international stakeholders in the field of diabetes. © 2015 American Association for Clinical Chemistry. Source


Miller W.G.,Virginia Commonwealth University | Jones G.R.D.,University of New South Wales | Horowitz G.L.,Harvard University | Weykamp C.,Queen Beatrix Hospital
Biochimica Clinica | Year: 2013

Proficiency testing or EQA is intended to verify on a recurring basis that laboratory results conform to expectations for the quality required for patient care. Key factors for interpreting EQA results are knowledge of the commutability of the samples used and the process used for target value assignment. A commutable EQA sample demonstrates the same numeric relationship between different measurement procedures as that expected for patients' samples. Noncommutable EQA samples frequently have a matrix-related bias of unknown magnitude that limits interpretation of results. EQA results for commutable samples can be used to assess accuracy against a reference measurement procedure or a designated comparison method. In addition, the agreement of the results between different measurement procedures for commutable samples reflects that which would be seen for patients' samples. EQA results for noncommutable samples must be compared to a peer group mean/median of results from participants who use measurement procedures that are expected to have the same or very similar matrix-related bias. Peer group evaluation is used to asses whether a laboratory is using a measurement procedure in conformance to the manufactur er' s specifications and/or in conformanc e t o ot her labor atori es u sing the same technology. A noncommutable EQA sample does not give meaningful information about the relationship of results for patients' samples between different measurement procedures. EQA provides substantial value to the practice of laboratory medicine by assessing the performance of individual laboratories and, when commutable samples are used, the status of standardization or harmonization among different measurement procedures. Source


Von Birgelen C.,Thoraxcentrum Twente | Von Birgelen C.,University of Twente | Sen H.,Thoraxcentrum Twente | Lam M.K.,Thoraxcentrum Twente | And 17 more authors.
The Lancet | Year: 2014

Background: Third-generation, permanent-polymer-based drug-eluting stents with novel, flexible designs might be more easily delivered than previous generations of stents in complex coronary lesions, but might be less longitudinally stable. We aimed to assess the safety and efficacy in all-comer patients of two third-generation stents that are often used clinically, but that have not yet been compared, and one of which has not previously been assessed in a randomised trial. Methods: In this investigator-initiated, single-blind, multicentre, randomised, two-arm, non-inferiority trial, patients aged 18 years and older who required a percutaneous coronary intervention with implantation of a drug-eluting stent were recruited from four study sites in the Netherlands. We randomly assigned patients by independently managed computer-generated allocation sequences in a 1:1 ratio to receive either cobalt-chromium-based zotarolimus-eluting stents (Resolute Integrity, Medtronic, Santa Rosa, CA, USA) or platinum-chromium-based everolimus-eluting stents (Promus Element, Boston Scientific, Natick, MA, USA). Patients and analysts were masked to the allocated stent, but treating clinicians were not. The primary endpoint of target-vessel failure was a composite of safety (cardiac death or target-vessel-related myocardial infarction) and efficacy (target-vessel revascularisation) at 12 months, analysed by intention to treat (with a non-inferiority margin of 3·6%). This trial is registered with ClinicalTrials.gov, number NCT01331707. Findings: Between Nov 25, 2010, and May 24, 2012, 1811 eligible all-comer patients, with 2371 target lesions, were enrolled in the study. 370 (20%) patients presented with ST-elevation myocardial infarction and 447 (25%) with non-ST-elevation myocardial infarction. 906 patients were assigned to receive zotarolimus-eluting stents and 905 to receive everolimus-eluting stents. Ease of stent delivery was shown by very low numbers of patients requiring treatment other than their assigned study treatment (six [1%] in the zotarolimus-eluting stent group vs five [1%] in the everolimus-eluting stent group; p=0·22). 12-month follow-up results were available for 1810 patients (one patient in the zotarolimus-eluting stent group withdrew consent). The primary endpoint was met by 55 (6%) of 905 patients in the zotarolimus-eluting stent group and 47 (5%) of 905 in the everolimus-eluting stent group. The zotarolimus-eluting stent was non-inferior to the everolimus-eluting stent (absolute risk diff erence 0·88%, 95% CI-1·24% to 3·01%; upper limit of one-sided 95% CI 2·69%; non-inferiority p=0·006). We noted no significant between-group diff erences in individual components of the primary endpoint. Definite stent thrombosis occurred in three (0·3%) patients in the zotarolimus-eluting stent group and six (0·7%) patients in the everolimus-eluting stent group (p=0·34). Longitudinal stent deformation was seen only in the everolimus-eluting stent group (nine [1·0%] of 905 vs 0 of 906, p=0·002; nine of 1591 [0·6%] everolimus-eluting stents implanted became deformed), but was not associated with any adverse events. Interpretation: Both stents were similarly efficacious and safe, and provided excellent clinical outcomes, especially in view of the large number of patients who presented with acute myocardial infarctions. Funding: Boston Scientific, Medtronic. Source


Langlois M.R.,European Federation of Clinical Chemistry and Laboratory Medicine EFLM | Langlois M.R.,Ghent University | van der Laarse A.,Leiden University | Weykamp C.,Queen Beatrix Hospital | And 11 more authors.
Atherosclerosis | Year: 2014

Background: Despite international standardization programs for LDLc and HDLc measurements, results vary significantly with methods from different manufacturers. We aimed to simulate the impact of analytical error and hypertriglyceridemia on HDLc- and LDLc-based cardiovascular risk classification. Methods: From the Dutch National EQA-2012 external quality assessment of 200 clinical laboratories, we examined data from normotriglyceridemic (~1mmol/l) and hypertriglyceridemic (~7mmol/l) serum pools with lipid target values assigned by the Lipid Reference Laboratory in Rotterdam. HDLc and LDLc were measured using direct methods of Abbott, Beckman, Siemens, Roche, Olympus, or Ortho Clinical Diagnostics. We simulated risk reclassification using HDL- and sex-specific SCORE multipliers considering two fictitious moderate-risk patients with initial SCORE 4% (man) and 3% (woman). Classification into high-risk treatment groups (LDLc >2.50mmol/l) was compared between calculated LDLc and direct LDLc methods. Results: Overall HDLc measurements in hypertriglyceridemic serum showed negative mean bias of-15%. HDL-multipliers falsely reclassified 70% of women and 43% of men to a high-risk (SCORE >5%) in hypertriglyceridemic serum (P<0.0001 vs. normotriglyceridemic serum) with method-dependent risk reclassifications. Direct LDLc in hypertriglyceridemic serum showed positive mean bias with Abbott (+16%) and Beckman (+14%) and negative mean bias with Roche (-7%). In hypertriglyceridemic serum, 57% of direct LDLc measurements were above high-risk treatment goal (2.50mmol/l) vs. 29% of direct LDLc (33% of calculated LDLc) in normotriglyceridemic sera. Conclusion: LDLc and HDLc measurements are unreliable in severe hypertriglyceridemia, and should be applied with caution in SCORE risk classification and therapeutic strategies. © 2014 Elsevier Ireland Ltd. Source


Van Imhoff D.E.,University of Groningen | Dijk P.H.,University of Groningen | Weykamp C.W.,Queen Beatrix Hospital | Cobbaert C.M.,Leiden University | Hulzebos C.V.,University of Groningen
European Journal of Pediatrics | Year: 2011

Accurate and precise bilirubin and albumin measurements are essential for proper management of jaundiced neonates. Data hereon are lacking for Dutch laboratories. We aimed to determine variability of measurements of bilirubin and albumin concentrations typical for (preterm) neonates. Aqueous, human serum albumin-based samples with different concentrations of bilirubin (100, 200, 300, 400, and 500 μmol/L) and albumin (0, 10, 15, 20, 25, and 30 g/L) were sent to laboratories of all Dutch neonatal intensive care units (n=10). Bilirubin and albumin recoveries of the specimens were measured using locally available routine analytical methods. The mean, standard deviation, and coefficients of variations (CV) were calculated per sample. Bilirubin concentrations were underestimated in the absence of albumin (maximal CV 26.0%). When the albumin concentration was 10 or 20 g/L, the bilirubin concentrations of the samples were overestimated (maximal CV 14.1% and 9.2%, respectively). Variability increased with higher weighed-in bilirubin concentrations. Measured albumin levels were ∼10% lower than albumin levels of manufactured samples. Bilirubin concentration did not influence albumin measurements. The maximal CV was 6.8%. In conclusion, interlaboratory variability of bilirubin and albumin measurements is high. Recalibration and introduction of a specific quality assessment scheme for neonatal samples is recommended to ensure exchangeability of bilirubin and albumin measurements among laboratories and to control the observed large variability. © 2011 The Author(s). Source