Source Type

Balunov B.F.,OAO Polzunov Research and Production Association for Research and Design of Power Equipment TsKTI | Belousov M.P.,OAO Polzunov Research and Production Association for Research and Design of Power Equipment TsKTI | Il'In V.A.,OAO Polzunov Research and Production Association for Research and Design of Power Equipment TsKTI | Saikova E.N.,OAO Polzunov Research and Production Association for Research and Design of Power Equipment TsKTI | And 2 more authors.
Thermal Engineering (English translation of Teploenergetika) | Year: 2011

We present the results obtained from experiments on determining condensate flowrate through the annular gaps at locations in which heat-transfer tubes pass through the holes in the horizontal spacer partitions used in vertical steam-water heaters. Expressions for calculating the coefficient of pressure drop due to friction λfr = f(Re) in real gaps are proposed on the basis of the obtained data. © 2011 Pleiades Publishing, Ltd.