Mulev Yu.V.,NPO YuMAS | Smirnov S.N.,Moscow Power Engineering Institute | Mulev M.Yu.,NPO YuMAS
Thermal Engineering (English translation of Teploenergetika) | Year: 2011

The results from experimental studies of the dielectric premiability of dry saturated steam in the temperature range from 388 to 614 K are presented, based on which an equation for calculating this constant is proposed. © Pleiades Publishing, Inc., 2011. Source


Mulev Y.V.,NPO YuMAS | Belyaeva O.V.,United Institute for Energy and Nuclear Research | Mulev M.Y.,NPO YuMAS | Saplitsa V.V.,United Institute for Energy and Nuclear Research | Zayats T.A.,United Institute for Energy and Nuclear Research
Thermal Engineering (English translation of Teploenergetika) | Year: 2011

It is shown that flow density must be estimated along with measuring the temperature (or pressure) for monitoring the state of two-phase medium. To this end, it is proposed to use a dielectric constant of coolant. A simple single-parameter relation is proposed, the use of which makes it possible to calculate the density of water and steam with the known values of temperature and dielectric constant in a concrete part of heattransfer equipment. © Pleiades Publishing, Inc., 2011. Source