Entity

Time filter

Source Type


Li G.-C.,Jiangsu Yanxin Science and Technology Incorporated Corporation | Dong S.-R.,Jiangsu Yanxin Science and Technology Incorporated Corporation | Tao G.-X.,Jiangsu Yanxin Science and Technology Incorporated Corporation | Tao X.,Jiangsu Yanxin Science and Technology Incorporated Corporation | Qin Y.-N.,Jiangsu Yanxin Science and Technology Incorporated Corporation
Petrochemical Equipment | Year: 2014

The design parameters of high pressure waste heat boiler of 800 kt/a methanol plant are out of standard range. Tube sheet connecting structure can't be calculated according to conventional design method. Through CFD simulation of the tube sheet temperature distribution, ANSYS finite element program was carried out on the tube sheet and connection structure stress analysis. Based on the provisions stipulated in JB 4732 - 1995 Steel Pressure Vessels - Design by Analysis, the results of the analysis were assessed, and the conclusion can be used as the reference in detail design. Source

Discover hidden collaborations