Japan Chemical Innovation and Inspection Institute

Kōtō-ku, Japan

Japan Chemical Innovation and Inspection Institute

Kōtō-ku, Japan
SEARCH FILTERS
Time filter
Source Type

Murakami R.,Japan Food Hygiene Association | Mutsuga M.,Japan National Institute of Health Sciences | Abe T.,Japan Food Research Laboratories | Abe Y.,Japan National Institute of Health Sciences | And 21 more authors.
Journal of the Food Hygienic Society of Japan | Year: 2015

An interlaboratory study was performed to evaluate a migration test method of antimony (Sb) and germanium (Ge), based on the Japanese Food Sanitation Law for food- contact polyethylene terephthalate. Eighteen laboratories participated, and quantified Sb and Ge in three test solutions as blind duplicates using graphite furnace atomic absorption spectrometry (GF-AAS), inductively coupled plasma-optical emission spectrometry (ICP-OES) or induced coupled plasma-mass spectrometry (ICP-MS). Statistical analysis revealed that the trueness, repeatability and reproducibility were 98-107%, 1.7-7.5% and 2.0-18.8% by using GF-AAS and ICP-OES. The performance of these methods is sufficient for testing the specifications. The performance parameters of ICP-MS were 99-106%, 0.7-2.2% and 2.2-10.5%, respectively. ICP-MS is available as an alternative measuring method. However, in some laboratories, the quantitative values of Sb were higher than the addition levels. We found that Sb in working solutions is absorbed on glass vessels. Careful control of concentration in working solutions is required for Sb analysis. © 2015, Food Hygienic Society of Japan. All rights reserved.


Shibata H.,Toyomi Center | Mutsuga M.,Japan National Institute of Health Sciences | Abe Y.,Japan National Institute of Health Sciences | Itou S.,Japan Food Hygiene Association | And 21 more authors.
Journal of the Food Hygienic Society of Japan | Year: 2015

Using six kinds of zinc solution in water and 4% acetic acid as samples, an interlaboratory study was performed to evaluate a zinc (Zn) test method for food-contact rubber products, based on the Japanese Food Sanitation Law. Eighteen laboratories participated, and quantified Zn in six test solutions as blind duplicates using flame atomic absorption spectrometry, induced coupled plasmaoptical emission spectrometry or induced coupled plasma-mass spectrometry. Statistical analysis revealed that the trueness, repeatability (RSDr) and reproducibility (RSDr) were 97-103%, 0.7- 4.9% and 1.7-8.9% by all measuring methods. The values of the performance parameter fulfilled the target value (trueness: 80-110%, RSDr: 10%, RSDr: 25%). The performance of these methods is sufficient for testing the adherence of samples to the specifications.


Mutsuga M.,Japan National Institute of Health Sciences | Abe T.,Japan Frozen Foods Inspection Corporation | Abe Y.,Japan National Institute of Health Sciences | Ishii R.,Saitama Prefectural Institute of Public Health | And 19 more authors.
Journal of the Food Hygienic Society of Japan | Year: 2014

An interlaboratory study was performed to evaluate a migration test method of cadmium (Cd) and lead (Pb), based on the Japanese Food Sanitation Law for glassware, ceramicware, enamelware and metal cans. Seventeen laboratories participated, and quantified Cd and Pb in eight test solutions as blind duplicates using flame atomic absorption spectrometry (AAS), graphite furnace atomic absorption spectrometry (GF-AAS), inductively coupled plasma-optical emission spectrometry (ICP-OES) or induced coupled plasma-mass spectrometry (ICP-MS). Statistical analysis revealed that the trueness, repeatability (RSDr) and reproducibility (RSDr) were 93-105%, 0.7-8.4% and 2.6-19.3% by using AAS, ICP-OES and ICP-MS (internal standard method). The performance of these methods is sufficient for testing specifications. However, some of the RSDr values exceeded 10% in GF-AAS, and careful control of accuracy is required.


Mutsuga M.,Japan National Institute of Health Sciences | Abe T.,Japan Frozen Foods Inspection Corporation | Abe Y.,Japan National Institute of Health Sciences | Ishii R.,Saitama Prefectural Institute of Public Health | And 20 more authors.
Journal of the Food Hygienic Society of Japan | Year: 2014

Based on the Japanese Food Sanitation Law, the performances of official and alternative material test methods for cadmium (Cd) and lead (Pb) in food contact plastics were compared. Nineteen laboratories participated to an interlaboratory study, and quantified Cd and Pb in three PVC pellets. in the official method,a sample is digested with H2SO4, taken up in HCl, and evaporated to dryness on a water bath, then measured by atomic absorption spectrometry (AAS) or inductively coupled plasma-optical emission spectrometry (ICP-OES). Statistical treatment revealed that the trueness, repeatability (RSDr) and reproducibility (RSDR) were 86-95%, 3.1-9.4% and 8.6-22.1%, respectively. The values of the performance parameters fulfilled the requirements , and the performances met the test specifications. The combination of evaporation to dryness on a hot plate and measurement by AAS or ICP-OES is applicable as an alternative method. However, the trueness and RSDr were inferior to those of the official method. The performance parameters obtained by using the microwave digestion method (MW method) to prepare test solution were better than those of the official method. Thus, the MW method is available as an alternative method. Induced coupled plasma-mass spectrometry (ICP-MS) is also available as an alternative method. However, it is necessary to ensure complete digestion of the sample.


Sonobe H.,Japan Recreation and Miscellaneous Goods Safety Laboratory | Mutsuga M.,Japan National Institute of Health Sciences | Abe T.,Japan Food Research Laboratories | Abe T.,Japan Food Hygiene Association | And 26 more authors.
Journal of the Food Hygienic Society of Japan | Year: 2016

Using polystyrene, acrylonitrile-styrene resin and acrylonitrile-butadiene-styrene resin pellets as samples, an interlaboratory study was performed to evaluate the volatiles test method, based on the specifications described in the Japanese Food Sanitation Law for food-contacting polystyrene products. The study was conducted with the participation of twenty-one laboratories. Each laboratory quantified the contents of styrene, toluene, ethylbenzene, isopropylbenzene and propylbenzene in three test pellets using GC-FID, GC-MS or headspace-GC-FID. Statistical analysis revealed that the repeatability (RSDr) and reproducibility (RSDr) were 1.0-2.6 and 2.5-5.5% for the GC-FID method. The values of the performance parameters fulfilled the requirements (RSDr: 10), RSDr: 25%), and the performance is sufficient for specifications testing. The RSDr and RSDr of results obtained using the GC-MS and HS-GC methods were 1.4-7.8 and 4.9-13% (GC-MS), and 2.0-2.6 and 3.3-6.9%(HS-GC-FID), respectively. The quantified levels were similar to those obtained with GC-FID. The study suggests that the GC-MS and HS-GC methods can be employed as alternative methods to the GC-FID method.


Shimura Y.,Japan Chemical Innovation and Inspection Institute | Suzuki J.,Japan Chemical Innovation and Inspection Institute | Muraoka M.,University of Tokyo | Kasuya M.C.Z.,University of Tokyo | And 2 more authors.
Preparative Biochemistry and Biotechnology | Year: 2012

The efficient production of ganglioside analogues was accomplished using RERF-LC-AI cells cultured in HYPERFlask (High Yield PERformance Flask). Eight kinds of ganglioside analogues (GM3, GM2, sialylparagloboside, GD3, di-sialylated lacto-N-tetraose, and another three kinds of analogues with intricate structures) were synthesized by the saccharide primer method using lung squamous-cell carcinoma line RERF-LC-AI and 12-azidododecyl β-lactoside primer. The yield for each analogue obtained using HYPERFlask was higher than yields obtained from 100-mm dishes. Copyright © Taylor & Francis Group, LLC.


PubMed | Japan Chemical Innovation and Inspection Institute
Type: Journal Article | Journal: Preparative biochemistry & biotechnology | Year: 2012

The efficient production of ganglioside analogues was accomplished using RERF-LC-AI cells cultured in HYPERFlask (High Yield PERformance Flask). Eight kinds of ganglioside analogues (GM3, GM2, sialylparagloboside, GD3, di-sialylated lacto-N-tetraose, and another three kinds of analogues with intricate structures) were synthesized by the saccharide primer method using lung squamous-cell carcinoma line RERF-LC-AI and 12-azidododecyl -lactoside primer. The yield for each analogue obtained using HYPERFlask was higher than yields obtained from 100-mm dishes.