San Lazzaro di Savena, Italy
San Lazzaro di Savena, Italy

Time filter

Source Type

Mancini B.,Geological and Environmental science | Scurti M.,Geological and Environmental science | Dormi A.,University of Bologna | Grottola A.,University of Modena and Reggio Emilia | And 2 more authors.
Environmental Science and Technology | Year: 2015

Contamination of hot water distribution systems by Legionella represents a great challenge due to difficulties associated with inactivating microorganisms, preserving the water characteristics. The aim of this study was to examine over the course of 1 year in 11 fixed sites, the impact of monochloramine disinfection on Legionella, heterotrophic bacteria (36°C), Pseudomonas aeruginosa contamination, and chemical parameters of a plumbing system in an Italian hospital. Three days after installation (T0), in the presence of monochloramine concentration between 1.5 and 2 mg/L, 10/11 sites (91%) were contaminated by L. pneumophila serogroups 3 and 10. After these results, the disinfectant dosage was increased to between 6 and 10 mg/L, reducing the level of Legionella by three logarithmic unit by 2 months postinstallation (T2) until 6 months later (T3). One year later (T4), there was a significant reduction (p = 0.0002) at 8/11 (73%) sites. Our data showed also a significant reduction of heterotrophic bacteria (36°C) in 6/11 (55%) sites at T4 (p = 0.0004), by contrast the contamination of P. aeruginosa found at T0 in two sites persisted up until T4. The results of the present study show that monochloramine is a promising disinfectant that can prevent Legionella contamination of hospital water supplies. © 2015 American Chemical Society.


PubMed | ITACA srl ITACA s.r.l. and University of Modena and Reggio Emilia
Type: Journal Article | Journal: Environmental science & technology | Year: 2015

Contamination of hot water distribution systems by Legionella represents a great challenge due to difficulties associated with inactivating microorganisms, preserving the water characteristics. The aim of this study was to examine over the course of 1 year in 11 fixed sites, the impact of monochloramine disinfection on Legionella, heterotrophic bacteria (36 C), Pseudomonas aeruginosa contamination, and chemical parameters of a plumbing system in an Italian hospital. Three days after installation (T0), in the presence of monochloramine concentration between 1.5 and 2 mg/L, 10/11 sites (91%) were contaminated by L. pneumophila serogroups 3 and 10. After these results, the disinfectant dosage was increased to between 6 and 10 mg/L, reducing the level of Legionella by three logarithmic unit by 2 months postinstallation (T2) until 6 months later (T3). One year later (T4), there was a significant reduction (p = 0.0002) at 8/11 (73%) sites. Our data showed also a significant reduction of heterotrophic bacteria (36 C) in 6/11 (55%) sites at T4 (p = 0.0004), by contrast the contamination of P. aeruginosa found at T0 in two sites persisted up until T4. The results of the present study show that monochloramine is a promising disinfectant that can prevent Legionella contamination of hospital water supplies.

Loading ITACA Srl ITACA S.r.l. collaborators
Loading ITACA Srl ITACA S.r.l. collaborators