Breus V.I.,Jsc I I Polzunov Scientific And Development Association On Research And Design Of Power Equipment | Barannikov A.B.,Jsc I I Polzunov Scientific And Development Association On Research And Design Of Power Equipment | Anisimova O.L.,Jsc I I Polzunov Scientific And Development Association On Research And Design Of Power Equipment | Petukhova V.F.,Jsc I I Polzunov Scientific And Development Association On Research And Design Of Power Equipment | And 2 more authors.
Power Technology and Engineering | Year: 2014

The drum internals and the internal arrangement of BKZ-75-39FB steam boiler were modified to improve the quality of steam to comply with the ratings of MAN Turbo AG MARC4-CO1 turbine. The commissioning tests of separators confirmed the decisions made. The continuous blowdown rate was about 1% over the entire capacity range. © 2014 Springer Science+Business Media New York. Source