Forster E.,Karlsruhe Institute of Technology | Schmidt A.,HYDAC International GmbH | Rhein F.,Karlsruhe Institute of Technology | Anlauf H.,Karlsruhe Institute of Technology | Nirschl H.,Karlsruhe Institute of Technology
Chemical Engineering and Technology | Year: 2016

An innovative magnetic filter in combination with a Mandhala magnet for oil filtration processes has been developed. With this filter design also nonmagnetizable particles can be separated. Responsible are hetero agglomeration processes that arise due to agglomeration of magnetizable with nonmagnetizable particles. Separation efficiencies in dependence of the particle size distribution and particle shape are quantitatively determined. An evaluation method for the quantification of the separation efficiency of nonmagnetizable particles is developed and validated by experimental data. On this basis, a statement about the efficiency of the hetero agglomeration can finally be made. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim. Source

Bauer F.,HYDAC International GmbH | Kleber J.,HYDAC International GmbH | Meindorf T.,Argo Hytos GmbH
Olhydraulik und Pneumatik | Year: 2011

O+P 11-12/2010 reported on pages 448 to 452 about the motivation for the monitoring of the oil condition and the fundamentals of oils and solid impurities. O+P 1-2/2011 on pages 32 to 37 presented information on the different procedures of particle measurement technology and the corresponding devices and their application. The continuation deals in detail with the oil condition measurement technology, the signal output as well as the application and product examples. Source