Entity

Time filter

Source Type


Diaz R.,Jaume I University | Pozo O.J.,Bioanalysis and Analytical Services Research Group | Sancho J.V.,Jaume I University | Hernandez F.,Jaume I University
Food Chemistry | Year: 2014

In this work, hybrid quadrupole time-of-flight mass spectrometer (QTOF MS) coupled to ultra high performance liquid chromatography (UHPLC) has been used for biomarkers identification for correct authentication of Valencia (Spain) oranges. Differentiation from foreign Argentinean, Brazilian and South African oranges has been carried out using XCMS application and multivariate analysis to UHPLC-(Q)TOF MS data acquired in both, positive and negative ionisation modes. Several markers have been found and corroborated by analysing two seasons samples. A seasonal independent marker was found and its structure elucidated using accurate mass data and MSE fragmentation spectrum information. Empirical formula was searched in Reaxys database applying sub-structure filtering from the fragments obtained. Three possible structures were found and citrusin D, a compound present in sweet oranges, has been identified as the most plausible as it fits better with the product ion scan performed for this compound. As a result of data obtained in this work, citrusin D is suggested as a potential marker to distinguish the geographic origin of oranges. © 2014 Elsevier Ltd. All rights reserved. Source


Gomez C.,Bioanalysis and Analytical Services Research Group | Gomez C.,University Pompeu Fabra | Segura J.,Bioanalysis and Analytical Services Research Group | Segura J.,University Pompeu Fabra | And 9 more authors.
Analytical and Bioanalytical Chemistry | Year: 2010

The objective of the present study was to investigate mesocarb metabolism in humans. Samples obtained after administration of mesocarb to healthy volunteers were studied. The samples were extracted at alkaline pH using ethyl acetate and salting-out effect to recover metabolites excreted free and conjugated with sulfate. A complementary procedure was applied to recover conjugates with glucuronic acid or with sulfate consisting of the extraction of the urines with XAD-2 columns previously conditioned with methanol and deionized water; the columns were then washed with water and finally eluted with methanol. In both cases, the dried extracts were reconstituted and analyzed by ultra-performance liquid chromatography-tandem mass spectrometry. Chromatographic separation was carried out using a C18 column (100 mm × 2.1 mm i.d., 1.7 μm particle size) and a mobile phase consisting of water and acetonitrile with 0.01% formic acid with gradient elution. The chromatographic system was coupled to a mass spectrometer with an electrospray ionization source working in positive mode. Metabolic experiments were performed in multiple-reaction monitoring mode by monitoring one transition for each potential mesocarb metabolite. Mesocarb and 19 metabolites were identified in human urine, including mono-, di-, and trihydroxylated metabolites excreted free as well as conjugated with sulfate or glucuronic acid. All metabolites were detected up to 48 h after administration. The structures of most metabolites were proposed based on data from reference standards available and molecular mass and product ion mass spectra of the peaks detected. The direct detection of mesocarb metabolites conjugated with sulfate and glucuronic acid without previous hydrolysis has been described for the first time. Finally, a screening method to detect the administration of mesocarb in routine antidoping control analyses was proposed and validated based on the detection of the main mesocarb metabolites in human urine (p-hydroxymesocarb and p-hydroxymesocarb sulfate). After analysis of several blank urines, the method demonstrated to be specific. Extraction recoveries of 100.3 ± 0.8 and 105.9 ± 10.8 (n = 4), and limits of detection of 0.5 and 0.1 ng mL-1 were obtained for p-hydroxymesocarb sulfate and p-hydroxymesocarb, respectively. The intra- and inter-assay precisions were estimated at two concentration levels, 50 and 250 ng mL-1, and relative standard deviations were lower than 15% in all cases (n = 4). © 2010 Springer-Verlag. Source

Discover hidden collaborations